TECHNICAL DATA
|
|
|
Specifications
Three Phase Current
30, 440 c.f.m. @ 0.192” W.G.
(Up to 48pa) Shed Resistance
|
· 1.5 kW ( 2 hp ) x Three Phase · 2.9 Operating amps · Three Phase · Double Belt Drive · Motor: 1400 r.p.m. / Fan Impeller: 415 r.p.m · Spring tension motor mounting (no adjustment required) · Fan drive shaft with sealed bearings · Standard “A” section belts · Variable pitch · 8 smooth nylon aerofoil shape blades · Segmented hub · Easy to remove fan taper lock bush · Positive centrifugal open and close louver mechanism with stainless steel springs to close louvers · Nylon louver bushes · Fibreglass Venturi · Noise Level: 40 dBA @ 100 metres |
|
Application/s
|
· Tunnel Ventilation sheds with or without Evaporative Cooling Pads · Cross Flow Sheds with Wall Adjustable Flaps · Broiler Sheds · Breeder Sheds · Hydroponics · Livestock · Pigs · Rabbits |
|
Performance |
· Will not stall when resistance increases with shed air intakes becoming blocked · Will out perform all metal shaped blade fans |
|
Dimensions
|
Height: 1500mm Width: 1500mm Depth: 910mm *Dimensions above include guards* |
|
Construction
|
· Heavy duty sealed ball bearings · Adjustable fan blades and louvers · Not to be compared with light gauge imports |
|
Optional Extras |
Light Eliminators (spacing can either be 20mm or 40mm - depending upon application) |
|
Warranty |
1 Year from entry into operating service |